Changeset 11633
- Timestamp:
- 09/23/20 21:46:44 (4 years ago)
- Location:
- trunk
- Files:
-
- 2 edited
Legend:
- Unmodified
- Added
- Removed
-
trunk/module-webif.c
r11632 r11633 6519 6519 set_status_info(vars, p_stat_cur); 6520 6520 6521 if(cfg.http_showmeminfo || cfg.http_showuserinfo || cfg.http_showreaderinfo || cfg.http_showloadinfo || cfg.http_showecminfo || (cfg.http_showcacheexinfo && config_enabled(CS_CACHEEX)) ){6521 if(cfg.http_showmeminfo || cfg.http_showuserinfo || cfg.http_showreaderinfo || cfg.http_showloadinfo || cfg.http_showecminfo || (cfg.http_showcacheexinfo && config_enabled(CS_CACHEEX)) || (cfg.http_showcacheexinfo && config_enabled(CS_CACHEEX_AIO))){ 6522 6522 tpl_addVar(vars, TPLADD, "DISPLAYINFO", "visible"); 6523 6523 } … … 6533 6533 tpl_addVar(vars, TPLADD, "DISPLAYECMINFO_READERS", cfg.http_showecminfo ? "visible" : "hidden"); 6534 6534 6535 if(cfg.http_showcacheexinfo == 1 && config_enabled(CS_CACHEEX)){ 6536 tpl_addVar(vars, TPLADD, "DISPLAYCACHEEXINFO", "visible"); 6537 tpl_addVar(vars, TPLADD, "DISPLAYCACHEEXAIOINFO", "visible"); 6535 if(cfg.http_showcacheexinfo == 1 && config_enabled(CS_CACHEEX)) 6536 { 6537 if (config_enabled(CS_CACHEEX_AIO)) 6538 { 6539 tpl_addVar(vars, TPLADD, "DISPLAYCACHEEXINFO", "hidden"); 6540 tpl_addVar(vars, TPLADD, "DISPLAYCACHEEXAIOINFO", "visible"); 6541 } 6542 else 6543 { 6544 tpl_addVar(vars, TPLADD, "DISPLAYCACHEEXINFO", "visible"); 6545 tpl_addVar(vars, TPLADD, "DISPLAYCACHEEXAIOINFO", "hidden"); 6546 } 6538 6547 } 6539 6548 else{ -
trunk/webif/config/cacheaio.html
r11623 r11633 4 4 <TR><TD><A>Delay:</A></TD><TD><input name="delay" class="withunit short" type="text" maxlength="5" value="##CACHEDELAY##"> ms delaying answers from cache</TD></TR> 5 5 <TR><TD><A>Max time:</A></TD><TD><input name="max_time" class="withunit short" type="text" maxlength="5" value="##MAXCACHETIME##"> s keep ECMs in cache</TD></TR> 6 <TR><TD><A>CW Cache Settings:</A></TD><TD><input name="cw_cache_settings" type="text" maxlength="1400" value="##CWCACHESETTINGS##"><br />Format: caid[&mask][@provid][$servid]:mode:timediff_old_cw[,n]</TD></TR>7 <TR><TD><A>CW Cache Size:</A></TD><TD><input name="cw_cache_size" class="withunit short" type="text" maxlength="20" value="##CWCACHESIZE##"> count of max. CWs for CW cache </TD></TR>8 <TR><TD><A>CW Cache Memory:</A></TD><TD><input name="cw_cache_memory" class="withunit short" type="text" maxlength="5" value="##CWCACHEMEMORY##"> MB of max. memory used for CW cache size</TD></TR>9 <TR><TD><A>ECM droptime:</A></TD><TD><input name="ecm_cache_droptime" class="withunit" type="text" maxlength="2" value="##ECMDROPTIME##"><br /> s after known ECM requests are dropped</TD></TR>10 <TR><TD><A>ECM Cache Size:</A></TD><TD><input name="ecm_cache_size" class="withunit short" type="text" maxlength="20" value="##ECMCACHESIZE##"> count of max. ECMs for ECM cache </TD></TR>11 <TR><TD><A>ECM Cache Memory:</A></TD><TD><input name="ecm_cache_memory" class="withunit short" type="text" maxlength="5" value="##ECMCACHEMEMORY##"> MB of max. memory used for ECM cache size</TD></TR>12 6 ##TPLCONFIGCACHEEXAIOCSP## 13 7 ##TPLCONFIGCWCYCLE##
Note:
See TracChangeset
for help on using the changeset viewer.