Changeset 3984
- Timestamp:
- 11/24/10 21:28:31 (13 years ago)
- Location:
- trunk/Distribution/doc
- Files:
-
- 2 edited
Legend:
- Unmodified
- Added
- Removed
-
trunk/Distribution/doc/man/oscam.server.5
r3880 r3984 341 341 .RE 342 342 .PP 343 \fBtiger_ideakey\fP = \fBIDEA key\fP344 .RS 3n345 IDEA key for Tiger Nagravision SCs346 .RE347 .PP348 343 \fBaeskey\fP = \fBAES key\fP 349 344 .RS 3n -
trunk/Distribution/doc/txt/oscam.server.txt
r3880 r3984 1 oscam.server(5) 1 oscam.server(5) oscam.server(5) 2 2 3 3 … … 7 7 8 8 SYNOPSIS 9 The server configuration file for OSCam contains reader parameters. sections in oscam.server are recurring (more than one reader possi‐10 ble). At least one [reader] section is required.9 The server configuration file for OSCam contains reader parameters. sections in oscam.server are recurring (more 10 than one reader possible). At least one [reader] section is required. 11 11 12 12 DESCRIPTIONS … … 26 26 constantcw: constant CW file name 27 27 28 constant CW file format: CA (4 digits):ID (6 digits):SID (4 digits):PMT PID (4 digits):ECM PID (4 digits):key (16 Bytes seperated by29 spaces)28 constant CW file format: CA (4 digits):ID (6 digits):SID (4 digits):PMT PID (4 digits):ECM PID (4 digits):key 29 (16 Bytes seperated by spaces) 30 30 31 31 example: 1234:123456:1234:1234:1234:00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F … … 71 71 72 72 logport = 0|port 73 camd3 reader logport, camd3 UDP must be activated, only works if there's no camd3 cascading, 0=disabled, default=0 73 camd3 reader logport, camd3 UDP must be activated, only works if there's no camd3 cascading, 0=disabled, 74 default=0 74 75 75 76 caid = CAID[&<mask>][,CAID[&<mask>]]... … … 93 94 94 95 mhz = frequency 95 set reader frequency in units of 10 kHz, if mhz > cardmhz you are in overclocking mode, refer to OVERCLOCKING, default:357 96 set reader frequency in units of 10 kHz, if mhz > cardmhz you are in overclocking mode, refer to OVERCLOCKING, 97 default:357 96 98 97 99 deprecated = 0|1 98 Frist the SC will be initialized in normal mode. If it fails, the SC will be automatically reverted to deprecated mode, so that the SC 99 speed will not be changed and the communication will remain on normal ATR speed of 9600 baud. 100 Frist the SC will be initialized in normal mode. If it fails, the SC will be automatically reverted to depre‐ 101 cated mode, so that the SC speed will not be changed and the communication will remain on normal ATR speed of 102 9600 baud. 100 103 101 104 1 = use deprecated SC mode only, default:0 … … 188 191 189 192 readnano = [path]filename 190 write file (usually a copy of a file saved by savenano) to your smartcard, if no path is specified, the specified file is searched for191 in the configuration directory, only valid for physical readers, default:none193 write file (usually a copy of a file saved by savenano) to your smartcard, if no path is specified, the speci‐ 194 fied file is searched for in the configuration directory, only valid for physical readers, default:none 192 195 193 196 example: readnano = write.emm … … 244 247 RSA key for Tiger Nagravision SCs 245 248 246 tiger_ideakey = IDEA key247 IDEA key for Tiger Nagravision SCs248 249 249 aeskey = AES key 250 250 16 bytes AES key for Viaccess SCs 251 251 252 aeskeys = CAID #0@ident:AES key #0 CAID #0[,AES key #1 CAID #0],...[;CAID #1@ident:AES key #0 CAID #1[,AES key #1 CAID #1],...]... 252 aeskeys = CAID #0@ident:AES key #0 CAID #0[,AES key #1 CAID #0],...[;CAID #1@ident:AES key #0 CAID #1[,AES key #1 253 CAID #1],...]... 253 254 multiple 16 bytes AES keys for Viaccess SCs 254 255 … … 279 280 · Dreambox and other internal readers 280 281 281 For Dreambox and other internal readers the highest possible clockrate will be auto detected. The mhz parameter lets you override the 282 values chosen by OSCam, if it differs from 357 and 358, but usually you will not set any value for mhz. 283 284 For certain Dreamboxes (especially PPC clones) the default mhz parameter leads to slow ECM times and/or "not found" ECMs. By setting mhz 285 to values like 200, 300, 400, ... 1600 you can find a value that works for your receiver and your card. The higher the mhz value, the 286 slower the ECM time (strange enough). 287 288 If you choose the value too low, your card is not recognized (no ATR or "card not supported"). If you choose the value too high, you get 289 slow ECM times. Our experience is that either no mhz line, or a line mhz = 1000 works best. 282 For Dreambox and other internal readers the highest possible clockrate will be auto detected. The mhz parameter 283 lets you override the values chosen by OSCam, if it differs from 357 and 358, but usually you will not set any 284 value for mhz. 285 286 For certain Dreamboxes (especially PPC clones) the default mhz parameter leads to slow ECM times and/or "not 287 found" ECMs. By setting mhz to values like 200, 300, 400, ... 1600 you can find a value that works for your 288 receiver and your card. The higher the mhz value, the slower the ECM time (strange enough). 289 290 If you choose the value too low, your card is not recognized (no ATR or "card not supported"). If you choose 291 the value too high, you get slow ECM times. Our experience is that either no mhz line, or a line mhz = 1000 292 works best. 290 293 291 294 · Phoenix / Smartmouse reader 292 295 293 Overclocking does not work with Windows and Mac OS X. Set mhz equivalent to the frequency of the reader. OSCam can not set the fre‐294 quency of the reader.296 Overclocking does not work with Windows and Mac OS X. Set mhz equivalent to the frequency of the reader. 297 OSCam can not set the frequency of the reader. 295 298 296 299 · Smargo Smartreader+ … … 298 301 Set the reader frequency with the native Smargo Smartreader+ tool (srp_tools). Do not set mhz and cardmhz. 299 302 300 OSCam tries to set the baudrate automatically. A standard serial port has limited baudrate settings, so SC overclocking might not work. 301 When using a serial reader the best way for overclocking is connecting it to a FTDI based USB to serial port adapter. 302 303 If overclocking does not work, verify the effective baudrate in the logfile. If it deviates too much from the requested baudrate, the SC 304 will not be recognized (no ATR) and the value for mhz should be adjusted again. The higher the baudrate, the more accurate the effective 305 baudrate can be. 303 OSCam tries to set the baudrate automatically. A standard serial port has limited baudrate settings, so SC over‐ 304 clocking might not work. When using a serial reader the best way for overclocking is connecting it to a FTDI 305 based USB to serial port adapter. 306 307 If overclocking does not work, verify the effective baudrate in the logfile. If it deviates too much from the 308 requested baudrate, the SC will not be recognized (no ATR) and the value for mhz should be adjusted again. The 309 higher the baudrate, the more accurate the effective baudrate can be. 306 310 307 311 EXAMPLES … … 396 400 397 401 SEE ALSO 398 list_smargo(1), oscam(1), oscam.ac(5), oscam.cert(5), oscam.conf(5), oscam.dvbapi(5), oscam.guess(5), oscam.ird(5), oscam.provid(5),399 oscam. services(5), oscam.srvid(5), oscam.tiers(5), oscam.user(5)400 401 402 403 402 list_smargo(1), oscam(1), oscam.ac(5), oscam.cert(5), oscam.conf(5), oscam.dvbapi(5), oscam.guess(5), 403 oscam.ird(5), oscam.provid(5), oscam.services(5), oscam.srvid(5), oscam.tiers(5), oscam.user(5) 404 405 406 407 oscam.server(5)
Note:
See TracChangeset
for help on using the changeset viewer.