Opened 13 years ago
Closed 13 years ago
#1212 closed defect (fixed)
Displayed Process ID is wrong
Reported by: | jx | Owned by: | alno |
---|---|---|---|
Priority: | minor | Component: | Webinterface |
Severity: | low | Keywords: | |
Cc: | Sensitive: | no |
Description
Revision
#3833 on i686-pc-linux
Issue Description
Displayed "Process ID" on bottom of webif page is always realPID-1.
For example: ps ax show PID 13842, webif show 13841.
When the issue occurs
Always
How the issue is reproducable
Start oscam on i686 linux, use command ps ax.
Attachments (1)
Change History (6)
comment:1 by , 13 years ago
follow-up: 4 comment:3 by , 13 years ago
But with this pid variable is just set if webif is included.
by , 13 years ago
Attachment: | oscam.c.patch added |
---|
server_pid currently only used in WebIf. For global use try patch v2.
comment:5 by , 13 years ago
Resolution: | → fixed |
---|---|
Status: | new → closed |
Note:
See TracTickets
for help on using tickets.
True, i also confirm.