Issue Description
Irdeto 0650 are not being writen to reader because of a EMM PID mismatch
When the issue occurs
When trying to update card
How the issue is reproducable
Connect using an user which has AU permission, and the EMM arrives fine to OSCAM (as seen on log), but it saids:
reader_caid 0650 != emmpid caid 0000 -> SKIP!
With revision r9847 (by example) it works perfect.
Attachments (1)
Change History (2)
by , 9 years ago
comment:1 by , 9 years ago
Resolution: | → fixed |
---|---|
Status: | new → closed |
according to logs this has been fixed with 10630
Note: