Opened 8 years ago
Closed 7 years ago
#4447 closed defect (fixed)
Seca card (NC+) "[pcsc] card system not supported"
Reported by: | Pouche | Owned by: | |
---|---|---|---|
Priority: | critical | Component: | Reader |
Severity: | high | Keywords: | Cyfra NC+ |
Cc: | Sensitive: | no |
Description
Revision
11222
Issue Description
I update oscam from old revision 8243 (all work OK) to new revison 11222.
Compiling without problems with LIBUSB and PCSC.
Now Oscam detect but not recognise and not work with SECA card in PCSC reader.
When the issue occurs
After update to revision 11222
How the issue is reproducable
Always
<Don't forget to ATTACH (NOT post here as text) a log file of oscam in debug mode (start oscam with -d255) and to remove the brackets around the fields! Otherwise, your ticket will be closed as you seem to be unable to read.>
Attachments (3)
Change History (10)
by , 8 years ago
comment:1 by , 8 years ago
Resolution: | → invalid |
---|---|
Status: | new → closed |
comment:2 by , 8 years ago
Resolution: | invalid |
---|---|
Status: | closed → reopened |
This is REAL bug !
I have all parameters correct in oscam.server
This settings are correct and corresponded with http://www.streamboard.tv/wiki/OSCam/en/Config/oscam.server#caid
I add here file with filtered data from oscam.log, only READER data.
And file with my oscam.server (I try many mhz and cardmhz)
by , 8 years ago
Attachment: | oscam(reader).log added |
---|
by , 8 years ago
Attachment: | oscam.server added |
---|
comment:3 by , 8 years ago
Please try this:
[reader] label = cyfra protocol = pcsc device = 0 services = cyfra caid = 0100 detect = cd group = 1 emmcache = 1,2,15,0
Simpler version of reader with autospeed enabled by default.
I don't have any problems with seca nc+ on pcsc reader.
comment:4 by , 8 years ago
Compile a version of OScam without Nagra support just Seca this will prevent the switch of the card into Nagra and back to Seca (which fails in your case). But you should discuss this on the forum!
comment:5 by , 8 years ago
@khimtiki; I test Your config but do not change anything.
@pr2; I compile r11224 without nagra and this version working ok!!!
BUT!!,
I have two cards: Seca in PCSC reader and NAGRA(Polsat) in SMARTREADER, and I need to use both of this systems.
In new version OSCAM it's impossible to work two local cards SECA and NAGRA?
Sorry for use Tickets system, but If this is not a bug, it is what it is?
I found this : http://www.streamboard.tv/oscam/changeset/9853
As you can see this is a bug and that's a long time. Make him a ticket, because this bug is still active (for me).
comment:6 by , 8 years ago
"detect_seca_nagra_tunneled_card" setting has been added with r11253.
Please set it to 0 for your seca card reader and try again.
comment:7 by , 7 years ago
Resolution: | → fixed |
---|---|
Status: | reopened → closed |
This ticket should not remains open since change: http://www.streamboard.tv/oscam/changeset/11253
Please use the forum to discuss your issue you came from a very old version of OScam some parameters units values have changed in between.
This is a ticketing system to report real bugs, use forum first to discuss your local problem.