Opened 6 years ago
#4534 new defect
Error when writing EMM with Polsat Cyfrowy (caid 1861)
Reported by: | FrogDR | Owned by: | |
---|---|---|---|
Priority: | major | Component: | Card support |
Severity: | high | Keywords: | emm write error polsat cyfrowy |
Cc: | Sensitive: | no |
Description
Revision
every revision over r11163
Issue Description
2016/11/11 18:33:50 2CDEEE09 r (reader) polsat [nagra] T1 Resync command error, trying to reactivate!
2016/11/11 18:33:51 2CDEEE09 r (reader) polsat [nagra] ATR: 3F FF 95 00 FF 91 81 71 A0 47 00 44 4E 41 53 50 31 38 30 20 4D 65 72 30 30 30 28
2016/11/11 18:33:51 2CDEEE09 r (reader) polsat [nagra] Init card protocol T1, FI=9, F=512, D=16, N=255
2016/11/11 18:33:51 2CDEEE09 r (reader) polsat [nagra] Calculated work ETU is 7.11 us reader mhz = 450
2016/11/11 18:33:54 2CDEEE09 r (reader) polsat [nagra] Buffers readed 0 bytes total time_us 3099355
2016/11/11 18:33:54 2CDEEE09 r (reader) polsat [nagra] PLL Reader: ATR Fsmax is 5 MHz, clocking card to 4.50 Mhz (nearest possible mhz specified reader->mhz)
2016/11/11 18:33:54 2CDEEE09 r (reader) polsat [nagra] Card responded ok for ifsd request of 160
When the issue occurs
everytime when EMM goes to a card i`v got error like i write up.
How the issue is reproducable
about every 3min...
R11163 is the latest works without this error. I check what was a changeset in R11164 :
"Message:
NAGRA:
Additional EMM filtering for emms starting with 0x84 and 0x87 as used by e.g. MaxTV Tnx goes to Pr2 for delivering initial patch, I merely reworked it a bit so that not 3 additional filters will be setup!"
So something gose wrong with this update....